You are here: Re: Connecting to SQL server « MsSQL Server « IT news, forums, messages
Re: Connecting to SQL server

Posted by ggrater on 10/01/27 11:40

Although it might be a network issue, if Profiler and EM are still
running, it's likely not. The issue may be the connection management
in the Delphi and ASP application. Connections from host applications
should be opened, used and immediately closed in order to be available
for other users. If too many connections are being left open, at some
point, you'll run out. Since Profiler and EM already have a
connection, they still function normally.

I would look at the connection management in the Delphi and ASP
applications and maybe do an sp_who2 when things go sideways to see how
many connections are open.

BTW...EM and Profiler use the same type of connection the ASP and
Delphi application use and therefore, they are all talking to SQL
Server on the same port, 1433.

 